SUBJECTS
|
BROWSE
|
CAREER CENTER
|
POPULAR
|
LOGIN
Business Skills
|
Soft Skills
|
Basic Literacy
|
Certifications
About
|
Help
|
Privacy
|
Terms
|
Email
Search
Test your basic knowledge |
Ethernet Technologies
Start Test
Study First
Subject
:
it-skills
Instructions:
Answer 50 questions in 15 minutes.
If you are not ready to take this test, you can
study here
.
Match each statement with the correct term.
Don't refresh. All questions and answers are randomly picked and ordered every time you load a test.
This is a study tool. The 3 wrong answers for each question are randomly chosen from answers to other questions. So, you might find at times the answers obvious, but you will see it re-enforces your understanding as you take the test each time.
1. Displays entries in the Forwarding Information Base (FIB) for a specific interface
Switch(config)#errdisable recovery cause {all | {cause-name}}
The Punt adjacency
The switch port falls back to default setting of half duplex
Switch#show ip cef {interface} [detail]
2. What are the names of CEF optimisation techniques using specialised forwarding hardware?
Multilayer Switching
IEEE 802.3u
Accelerated CEF (aCEF) and Distributed CEF (dCEF)
Switch(config)#errdisable detect cause udld
3. Resets the configuration of a switch port to its default values
Enable error-disable for all possible causes
ARP requests and replies; IP packets requiring an ICMP response; IP broadcasts to be relayed; Routing protocol updates; CDP packets; Packets needing encryption; Packets triggering NAT; Other non-IP packets
They are dropped (ARP throttling)
Switch(config)#default interface {interface}
4. Displays the entire Forwarding Information Base (FIB)
Switch#show ip cef
Fast Ethernet over 2 pairs EIA/TIA Category 3 - 4 - 5 UTP
Switch(config)#interface {type}{module}/{number}
Interconnecting switches in a campus network
5. Enables error-disable when an interface has been looped back
Switch(config)#errdisable detect cause loopback
Switch(config)#errdisable detect cause channel-misconfig
Compiling Access Control Entries (ACE) into the TCAM table
SVI
6. What is the original standard for Ethernet (10 Mbps)?
Trunk
10 Gigabit Ethernet over 9 micron SMF (1310 nm serial laser)
Switch(config)#errdisable detect cause vmps
IEEE 802.3
7. Removes entries from the CAM table
Numeric values that represent what action to take after the TCAM lookup occurs
Only temporarily for debugging purposes
Switch(config)#errdisable detect cause psecure-violation
Switch#clear mac address-table [dynamic] [address {mac-address}] [interface {interface}] [vlan {vlan}]
8. What two IOS software components are involved in TCAM operation?
Manually by administratively disabling and re-enabling the port
IEEE 802.3ab
Feature Manager (FM) and Switching Database Manager (SDM)
The Drop adjacency
9. Where is source and destination addresses and other relevant protocol information for access lists stored in the TCAM table?
In TCAM Value entries
10 Gigabit Ethernet over 9 micron SMF (1550 nm serial laser)
Carrier Sense Multiple Access Collision Detection
70 km for 9 micron SMF; 100 km for 8 micron SMF
10. Displays the CAM table size with number of MAC addresses
Slow response times - low throughput - runts and other input errors on the switch ports
Switch#show mac address-table count [address {mac-address}] [interface {interface}] [vlan {vlan}]
ARP requests and replies; IP packets requiring an ICMP response; IP broadcasts to be relayed; Routing protocol updates; CDP packets; Packets needing encryption; Packets triggering NAT; Other non-IP packets
SC fibre optic or RJ-45 UTP
11. What is the standard for Gigabit Ethernet (1000 Mbps)?
IEEE 802.3z
Trunk
The table of learned MAC addresses - ports - and VLAN information
Switched virtual interface (SVI)
12. What is the TCAM Value and Mask for an IP access list?
Switch(config)#no ip cef
SC or MT-RJ
70 km for 9 micron SMF; 100 km for 8 micron SMF
Source IP (/32); Destination IP (/32); Protocol (/16); IP ToS (/8)
13. What information is stored in CAM?
275 metres for 62.5 micron MMF; 550 metres for 50 micron MMF
UTP Fast Ethernet and Gigabit Ethernet
Layer 2 destination address changed to next-hop MAC address; Layer 2 source address changed to outbound interface MAC address; Layer 3 TTL decremented by 1; Layer 3 IP checksum recalculated; Layer 2 frame checksum recalculated
The table of learned MAC addresses - ports - and VLAN information
14. How does topology based switching work?
Static access or dynamic
Layer 3 routing information builds and pre-populates a single database of the entire network topology; All table lookups are performed in hardware with the longest matching destination used in forwarding
Switch(config)#define interface-range {macro-name} {type} {module}/{number} [- {number}] [ - {type} {module}/{number} ...]
Switch(config-if)#description {string}
15. What is the state of packets that are sent to the CEF Layer 3 engine because of missing Layer 2 next-hop addresses?
A name assigned to a ranges of interfaces
Configure the appropriate values manually on both ends of the link
Feature Manager (FM) and Switching Database Manager (SDM)
CEF glean
16. Displays interface configuration information
Down - static access - trunk or tunnel
Switch#show running-config interface {interface}
Entry not in FIB; FIB table full; IP TTL expired; MTU exceeded; ICMP redirect; Unsupported encapsulation; Tunnelled packets requiring compression or encryption; Access list with 'log' option; NAT must be performed
550 metres for 50 or 62.5 micron MMF; 10 km for 9 micron SMF
17. What are GigaStack GBICs used for?
Cabling specifications for 10 Gigabit Ethernet
Switch#show cef drop
Source IPX network (/32); Destination IPX network (/32); Destination node (/48); IPX packet type (/16)
GBIC-to-GBIC connection between stacking Catalyst switches or between any two Gigabit switch ports over a short distance
18. What are the letters used with 10GBASE-X two-letter suffixes to specify the PHY type?
Switch#show errdisable detect
Partition and tune the TCAM on some Catalyst switches into areas for different functions
R = LAN PHY; W = WAN PHY
The adjacency table
19. What is CAM?
Switch(config-if)#shutdown
SC fibre optic or RJ-45 UTP
Content-Addressable Memory
Switch(config)#errdisable detect cause unicast-flood
20. What is the maximum cabling distance for Fast Ethernet over 62.5/125 micron multimode fibre?
Route caching and topology based
Switch#show mac address-table dynamic [address {mac-address}] [interface {interface}] [vlan {vlan}]
Forwarding Information Base
400 metres half duplex and 2000 metres full duplex
21. Displays a list with status of all interfaces
Switch#show cef not-cef-switched
Switch#show interfaces status
Switch(config)#errdisable detect cause dhcp-rate-limit
The Null adjacency
22. What is the name of the CEF engine that maintains routing information in software?
When there are more access list entries and Layer 4 operations than available Mask/Value and LOU entries
Stations can transmit and receive at the same time because switched Ethernet removes the possibility of collisions
The Layer 3 engine
Source IPX network (/32); Destination IPX network (/32); Destination node (/48); IPX packet type (/16)
23. Sets the speed of a Fast Ethernet or Gigabit Ethernet interface
Switch(config-if)#speed {10 | 100 | 1000 | auto}
Partition and tune the TCAM on some Catalyst switches into areas for different functions
Switch(config)#errdisable detect cause security-violation
A station must wait its turn to transmit; it can't transmit and receive at the same time
24. What are the common PMD types for 10 Gigabit Ethernet?
A proprietary connector with a high-data-rate copper cable with enhanced signal integrity and EMI performance
40 km
10GBASE-SR/SW - 10GBASE-LR/LW - 10GBASE-ER/EW - 10GBASE-LX4/LW4 - 10GBASE-CX4
A switch port that has been shut down automatically due to a serious error condition
25. What are the default error-disable detection causes?
Native routed interface
300 seconds
Enable error-disable for all possible causes
Slow response times - low throughput - runts and other input errors on the switch ports
26. Enables error-disable for rate-limiting of DHCP snooping
Switch(config)#errdisable recovery cause {all | {cause-name}}
Switch(config)#errdisable detect cause l2ptguard
Switch(config)#errdisable detect cause dhcp-rate-limit
The adjacency table
27. What is IEEE?
Gigabit Ethernet over 1 pair 8 or 9 micron SMF (1550 nm laser)
Institute of Electrical and Electronics Engineers
Static access or trunk
FIB with adjacency table
28. What are the letters used with 10GBASE-X two-letter suffixes to specify the transceiver wavelengths?
ANSI X3T11 FibreChannel
S = Short; L = Long; E = Extra-long
Per port collision domains; Full duplex mode; Dedicated bandwidth; Error detection; Broadcast thresholds; Intelligent filtering and forwarding
SC fibre optic or RJ-45 UTP
29. What is WWDM?
1 -2 on one end with 3 -6 on the other end - and 4 -5 on one end with 7 -8 on the other end
Wide-Wavelength Division Multiplexing
1 -2 on one end with 3 -6 on the other end
Incomplete adjacency; Incomplete ARP resolution; Unsupported packet features; ICMP redirect; Packets destined to the router itself; IP options present; Access list evaluation failure; Fragmentation failure
30. What is Cisco's old recommendation regarding switch port speed and duplex mode?
Switch(config)#errdisable detect cause storm-control
Configure the appropriate values manually on both ends of the link
Distributed CEF (dCEF)
1 -2 on one end with 3 -6 on the other end
31. What is the standard for 10 Gigabit Ethernet (10GbE)?
Half duplex
Store-and-forward
IEEE 802.3ae
Ingress queueing; Destination MAC lookup (CAM); Destination IP lookup (FIB); Security ACL lookup (TCAM); QoS ACL lookup (TCAM); Layer 3 packet rewrite; Egress queueing
32. What is the role of a Switch Engine (SE) in first generation MLS?
Source IP (/32); Destination IP (/32); Protocol (/16); ICMP code (/8); ICMP type (/4); IP type of service (ToS) (/8)
Switch(config)#errdisable detect cause gbic-invalid
Switch(config)#interface range macro {name}
Listen to the first packet and put its resulting destination in the MLS cache; Route subsequent packets in the same flow based on the MLS cache
33. What are the basic operations that a frame undergoes as it passes through a Layer 2 switch?
Ingress queueing; Destination MAC lookup (CAM); Security ACL lookup (TCAM); QoS ACL lookup (TCAM); Egress queueing
A proprietary connector with a high-data-rate copper cable with enhanced signal integrity and EMI performance
Switch(config)#errdisable detect cause channel-misconfig
The CEF epoch number
34. How are packets marked before being sent to the CEF Layer 3 engine for further processing?
Mask bits set to 1 for Value bits of interest and 0 for Value bits that don't matter
CEF punt
In TCAM Value entries
Switch(config)#errdisable detect cause gbic-invalid
35. When do collisions occur?
The CEF epoch number
Layer 2 source and destination MAC addresses; Layer 3 Time-To-Live (TTL) value and header checksum
1000BASE-T full duplex followed by 1000BASE-T half duplex
When one station transmits at the same time as another on a shared medium
36. What CEF adjacency is used to switch packets destined for the null interface?
Switch(config)#interface range macro {name}
The Null adjacency
On
Content-Addressable Memory
37. What is WAN PHY used for?
The table of learned MAC addresses - ports - and VLAN information
Gigabit Ethernet over 1 pair 50 or 62.5 micron MMF or 9 micron SMF (1300 nm laser)
Interconnecting with existing Synchronous Optical Network (SONET) or Synchronous Digital Hierarchy (SDH) networks
Switch(config)#errdisable detect cause {all | {cause-name}}
38. What are the reasons for packets being dropped by CEF?
Encapsulation failure; Unresolved address; Unsupported protocol; No valid route; No valid adjacency; Checksum error
10GBASE-SR/SW - 10GBASE-LR/LW - 10GBASE-ER/EW - 10GBASE-LX4/LW4 - 10GBASE-CX4
The Punt adjacency
IEEE 802.3z
39. Displays error-disabled detection status
Switch#show errdisable detect
Incomplete adjacency; Incomplete ARP resolution; Unsupported packet features; ICMP redirect; Packets destined to the router itself; IP options present; Access list evaluation failure; Fragmentation failure
Switch(config-if)#speed {10 | 100 | 1000 | auto}
The Layer 3 engine
40. What is the operational mode of a switch port that carries transparent Layer 2 VPNs?
Full duplex
Switch#show interfaces status err-disabled
Switch(config)#errdisable detect cause channel-misconfig
Tunnel
41. Disables a switch port
Bundling together two to eight full duplex Fast Ethernet links to act as a single physical link
Switch(config)#errdisable recovery interval {seconds}
Switch(config-if)#shutdown
Value - Mask - and Result (VMR)
42. Enables error-disable for conditions that trigger unicast flood blocking on a port
The table of learned MAC addresses - ports - and VLAN information
Switch(config)#errdisable detect cause unicast-flood
Static access or trunk
They are dropped (ARP throttling)
43. What is 1000BASE-LX/LH?
Full duplex if only one of the two stacking connectors is used; Half duplex over a shared bus if if both connectors are used
10GbE operates only at full duplex
Switch(config)#interface range {type}{module}/{number} [- {number}] [ - {type}{module}/{number} ...]
Gigabit Ethernet over 1 pair 50 or 62.5 micron MMF or 9 micron SMF (1300 nm laser)
44. What is 1000BASE-ZX?
Store-and-forward
Process the first packet in a traffic flow to determine the destination
Fast Ethernet over 4 pairs EIA/TIA Category 3 - 4 - 5 UTP
Gigabit Ethernet over 1 pair 8 or 9 micron SMF (1550 nm laser)
45. What happens when autonegotiating of link duplex mode fails on a Fast Ethernet link?
400 metres half duplex and 2000 metres full duplex
The switch port falls back to default setting of half duplex
70 km for 9 micron SMF; 100 km for 8 micron SMF
Switch#show adjacency [{interface}] [summary | detail]
46. What is 10GBASE-LX4/LW4?
A station must wait its turn to transmit; it can't transmit and receive at the same time
10 Gigabit Ethernet over 50 or 62.5 micron MMF or 9 micron SMF (1300 nm WWDM laser)
A proprietary connector with a high-data-rate copper cable with enhanced signal integrity and EMI performance
Layer 2 source and destination MAC addresses; Layer 3 Time-To-Live (TTL) value and header checksum
47. Selects multiple switch port interfaces at the same time and enters interface configuration mode
Gigabit Ethernet over 1 pair Shielded Twisted Pair (STP) cabling
Switch(config)#no ip cef
Switch(config)#interface range {type}{module}/{number} [- {number}] [ - {type}{module}/{number} ...]
Cabling specifications for 10 Gigabit Ethernet
48. What is the content of TCAM Result entries?
300 seconds
Switch#show adjacency [{interface}] [summary | detail]
Numeric values that represent what action to take after the TCAM lookup occurs
Switch(config)#errdisable detect cause bpduguard
49. What is LOU?
Logical Operation Unit
15 metres
Switch#show errdisable detect
Tunnel
50. What is the prerequesite for creating a working SVI?
Routing table and ARP table
Fast Ethernet over 2 pairs EIA/TIA Category 5 UTP
Switch(config)#errdisable detect cause {all | {cause-name}}
Creating the VLAN