SUBJECTS
|
BROWSE
|
CAREER CENTER
|
POPULAR
|
JOIN
|
LOGIN
Business Skills
|
Soft Skills
|
Basic Literacy
|
Certifications
About
|
Help
|
Privacy
|
Terms
Search
Test your basic knowledge |
Ethernet Technologies
Start Test
Study First
Subject
:
it-skills
Instructions:
Answer 50 questions in 15 minutes.
If you are not ready to take this test, you can
study here
.
Match each statement with the correct term.
Don't refresh. All questions and answers are randomly picked and ordered every time you load a test.
This is a study tool. The 3 wrong answers for each question are randomly chosen from answers to other questions. So, you might find at times the answers obvious, but you will see it re-enforces your understanding as you take the test each time.
1. What is the name of the switching technology where good frames are received - stored for inspection and then forwarded?
300 metres for 50 or 62.5 micron MMF; 10 km for 9 micron SMF
GBIC-to-GBIC connection between stacking Catalyst switches or between any two Gigabit switch ports over a short distance
Store-and-forward
Layer 3 routing information builds and pre-populates a single database of the entire network topology; All table lookups are performed in hardware with the longest matching destination used in forwarding
2. Creates a switched virtual interface (SVI) and enters interface configuration mode
Switch(config)#interface vlan {vlan-id}
CEF glean
1 -2 on one end with 3 -6 on the other end
Switch(config)#errdisable detect cause arp-inspection
3. What is EMI?
Electromagnetic Interference
Cabling specifications for Gigabit Ethernet
10 Gigabit Ethernet over 50 or 62.5 micron MMF (850 nm serial laser)
Wide-Wavelength Division Multiplexing
4. Enables error-disable when the Port Aggregation Protocol (PAgP) is flapping
Switch(config)#errdisable detect cause pagp-flap
Tunnel
LOU registers
By Mask/Value - where each unique mask has eight value patterns associated with it
5. Enables error-disable for errors when assigning a port to a dynamic VLAN through a VMPS
300 seconds
Switch(config)#errdisable detect cause vmps
Switch#show running-config interface {interface}
Layer 2 destination address changed to next-hop MAC address; Layer 2 source address changed to outbound interface MAC address; Layer 3 TTL decremented by 1; Layer 3 IP checksum recalculated; Layer 2 frame checksum recalculated
6. What is the maximum cabling distance for 10GBASE-ER/EW?
Switch#show running-config interface {interface}
Distributed CEF (dCEF)
Static access - trunk - tunnel or dynamic
40 km
7. What RJ-45 pins have been swapped in a Category 5 UTP crossover cable for Fast Ethernet?
Switch(config-if)#no switchport
1 -2 on one end with 3 -6 on the other end
Configure the appropriate values manually on both ends of the link
Switch(config)#errdisable detect cause psecure-violation
8. Enables error-disable when a storm control threshold has been exceeded on a port
Off
Switch(config)#errdisable detect cause storm-control
Static access or trunk
Switch(config)#no ip cef
9. Selects multiple switch port interfaces at the same time and enters interface configuration mode
Tunnel
Switch(config)#interface range {type}{module}/{number} [- {number}] [ - {type}{module}/{number} ...]
Source IP (/32); Destination IP (/32); Protocol (/16); ICMP code (/8); ICMP type (/4); IP type of service (ToS) (/8)
Switch#show errdisable recovery
10. What is the operational mode of a switch port that carries transparent Layer 2 VPNs?
SVI
Packets that have been truncated before they were fully received
Tunnel
S = Short; L = Long; E = Extra-long
11. What are the names of the two basic generations of MLS?
IEEE 802.3z
Route caching and topology based
Fast Ethernet over 4 pairs EIA/TIA Category 3 - 4 - 5 UTP
300 seconds
12. How is the TCAM organised?
Gigabit Ethernet over 1 pair 50 or 62.5 micron MMF or 9 micron SMF (1300 nm laser)
By Mask/Value - where each unique mask has eight value patterns associated with it
Switch#show mac address-table [address {mac-address}] [interface {interface}] [vlan {vlan}]
7 100BASE-T2 full duplex; 6 100BASE-TX full duplex; 5 100BASE-T2 half duplex; 4 100BASE-T4; 3 100BASE-TX; 2 10BASE-T full duplex; 1 10BASE-T
13. What is the standard for 10 Gigabit Ethernet (10GbE)?
Compiling Access Control Entries (ACE) into the TCAM table
Flooding a frame with unknown destination MAC address out all ports assigned to the source port VLAN except the source port itself
With a mask value in addition to binary values to decide which keys in a table are relevant
IEEE 802.3ae
14. What is unknown unicast flooding?
From 30 seconds to 86 -400 seconds (24 hours)
GBIC-to-GBIC connection between stacking Catalyst switches or between any two Gigabit switch ports over a short distance
Flooding a frame with unknown destination MAC address out all ports assigned to the source port VLAN except the source port itself
15 metres
15. What is a SVI?
Interconnecting with existing Synchronous Optical Network (SONET) or Synchronous Digital Hierarchy (SDH) networks
Off
100 metres
Switched virtual interface (SVI)
16. What is the name of a Layer 3 physical interface on a switch?
Native routed interface
Logical Operation Unit
With a mask value in addition to binary values to decide which keys in a table are relevant
Gigabit Interface Converter (GBIC) or Small Form factor Pluggable (SFP)
17. What tables are maintained by the CEF Layer 3 forwarding engine?
FIB with adjacency table
Source MAC address; Port of arrival; VLAN; Time stamp
Switch#show mac address-table count [address {mac-address}] [interface {interface}] [vlan {vlan}]
SVI
18. What information is stored in TCAM?
Security and QoS ACLs
Down - static access - trunk or tunnel
Source MAC address; Port of arrival; VLAN; Time stamp
Adjacent MAC address (6 octets); Layer 3 engine MAC address (6 octets); EtherType (2 octets)
19. What is the maximum cabling distance for 10GBASE-LX4/LW4?
70 km for 9 micron SMF; 100 km for 8 micron SMF
XENPAK - X2 - or SFP+
300 metres for 50 or 62.5 micron MMF; 10 km for 9 micron SMF
1000BASE-CX - 1000BASE-T - 1000-BASE-SX - 1000-BASE-LX/LH and 1000-BASE-ZX
20. Configures the maximum ageing time for entries in the MAC address table
Switch(config)#mac address-table aging-time {seconds}
Switch(config-if)#duplex {auto | full | half}
10 Gigabit Ethernet over 9 micron SMF (1310 nm serial laser)
Fast Ethernet over 62.5/125 micron multimode fibre (MMF) or 9 micron singlemode fibre (SMF)
21. What is WAN PHY used for?
Switch(config)#interface range {type}{module}/{number} [- {number}] [ - {type}{module}/{number} ...]
1000BASE-CX - 1000BASE-T - 1000-BASE-SX - 1000-BASE-LX/LH and 1000-BASE-ZX
Layer 2 destination address changed to next-hop MAC address; Layer 2 source address changed to outbound interface MAC address; Layer 3 TTL decremented by 1; Layer 3 IP checksum recalculated; Layer 2 frame checksum recalculated
Interconnecting with existing Synchronous Optical Network (SONET) or Synchronous Digital Hierarchy (SDH) networks
22. Displays administrative and operational status for a specified interface
FIB with adjacency table
Interconnecting switches in a campus network
Fast Ethernet over 2 pairs EIA/TIA Category 3 - 4 - 5 UTP
Switch#show interfaces {interface}
23. What is the administrative mode of a switch port that uses DTP to negotiate its operational mode?
S = Short; L = Long; E = Extra-long
Dynamic
Cabling specifications for Gigabit Ethernet
The Layer 3 engine
24. What is the maximum cabling distance for Fast Ethernet over 62.5/125 micron multimode fibre?
Process the first packet in a traffic flow to determine the destination
400 metres half duplex and 2000 metres full duplex
Fast Ethernet over 62.5/125 micron multimode fibre (MMF) or 9 micron singlemode fibre (SMF)
Switch(config)#errdisable detect cause unicast-flood
25. What are the classes of Physical Media Dependent (PMD) interfaces defined by IEEE 802.3ae?
LAN PHY and WAN PHY
Switch#show running-config interface {interface}
Interconnecting switches in a campus network
Switch(config)#errdisable detect cause dhcp-rate-limit
26. What is the TCAM Value and Mask for an IP access list?
10 km
Manually by administratively disabling and re-enabling the port
Source IP (/32); Destination IP (/32); Protocol (/16); IP ToS (/8)
Switch(config-if)#no switchport
27. What is WWDM?
Switch#show ip cef
Routing table and ARP table
Wide-Wavelength Division Multiplexing
The Layer 3 forwarding engine
28. Enables error-disable for the presence of invalid GBIC or SFP modules
Switch(config)#errdisable detect cause vmps
Ternary Content-Addressable Memory
IEEE 802.3ae
Switch(config)#errdisable detect cause gbic-invalid
29. How are ternary combinations implemented?
Content-Addressable Memory
Switch(config-if)#duplex {auto | full | half}
With a mask value in addition to binary values to decide which keys in a table are relevant
Institute of Electrical and Electronics Engineers
30. What is the name of physical network segment where data packets can collide with one another when being sent?
Switch#show adjacency [{interface}] [summary | detail]
Collision domain
Switch(config)#errdisable detect cause channel-misconfig
Through exchange of information - which means that for one end to successfully negotiate duplex mode the other end must also be set to autonegotiate
31. What is the maximum cabling distance for 1000BASE-LX/LH?
Off
10 Gigabit Ethernet over 9 micron SMF (1550 nm serial laser)
550 metres for 50 or 62.5 micron MMF; 10 km for 9 micron SMF
Switch(config)#errdisable detect cause arp-inspection
32. Specifies the timer for automatic re-enabling of error-disabled ports
Interconnecting switches in a campus network
The Punt adjacency
Switch(config)#errdisable recovery interval {seconds}
Switch(config)#errdisable detect cause l2ptguard
33. How are packets marked before being sent to the CEF Layer 3 engine for further processing?
CEF punt
Cisco Express Forwarding
Source MAC (/48); Destination MAC (/48); Ethertype (/16)
Half duplex
34. What is the prerequesite for creating a working SVI?
Accelerated CEF (aCEF)
Switch(config)#errdisable recovery cause {all | {cause-name}}
When there are more access list entries and Layer 4 operations than available Mask/Value and LOU entries
Creating the VLAN
35. Displays the contents of the CAM table
Switch#show mac address-table [address {mac-address}] [interface {interface}] [vlan {vlan}]
Flooding a frame with unknown destination MAC address out all ports assigned to the source port VLAN except the source port itself
The table of learned MAC addresses - ports - and VLAN information
25 metres
36. What RJ-45 pins must be swapped in a Category 5 UTP crossover cable for Gigabit Ethernet?
Switch(config)#errdisable detect cause dhcp-rate-limit
1 -2 on one end with 3 -6 on the other end - and 4 -5 on one end with 7 -8 on the other end
Cabling specifications for 10 Gigabit Ethernet
Switch(config)#interface vlan {vlan-id}
37. What is 1000BASE-X?
Cabling specifications for Gigabit Ethernet
Switch(config)#no ip cef
IEEE 802.3ae
Gigabit Ethernet over 1 pair 8 or 9 micron SMF (1550 nm laser)
38. What is the content of TCAM Mask entries?
39. How does topology based switching work?
LC - MT-RJ or RJ-45
Dynamic
Switch(config)#mac address-table static {mac-address} vlan {vlan} interface {interface}
Layer 3 routing information builds and pre-populates a single database of the entire network topology; All table lookups are performed in hardware with the longest matching destination used in forwarding
40. Sets the administrative mode of a switch port to access
Switch(config-if)#switchport mode access
ANSI X3T11 FibreChannel
With MMF cables shorter than 100 metres (to prevent over-driving the far-end receiver) and with MMF cables longer than 300 metres (to lessen the effect of differential mode delay)
Switch(config)#errdisable detect cause bpduguard
41. What is the maximum cabling distance for 1000BASE-CX?
Carrier Sense Multiple Access Collision Detection
25 metres
Half duplex
From 30 seconds to 86 -400 seconds (24 hours)
42. What is 10GBASE-LX4/LW4?
Switch(config-if)#switchport mode access
The Discard adjacency
Only temporarily for debugging purposes
10 Gigabit Ethernet over 50 or 62.5 micron MMF or 9 micron SMF (1300 nm WWDM laser)
43. What is 1000BASE-LX/LH?
ANSI X3T11 FibreChannel
Gigabit Ethernet over 1 pair 50 or 62.5 micron MMF or 9 micron SMF (1300 nm laser)
Switch(config)#errdisable detect cause storm-control
IEEE 802.3
44. What is TCAM?
Ternary Content-Addressable Memory
Switch(config)#errdisable detect cause dhcp-rate-limit
Compiling Access Control Entries (ACE) into the TCAM table
Half duplex
45. What combinations are TCAM entries composed of?
IEEE 802.3u
S = Short; L = Long; E = Extra-long
70 km for 9 micron SMF; 100 km for 8 micron SMF
Value - Mask - and Result (VMR)
46. Displays the CAM table size with number of MAC addresses
Switch#show mac address-table count [address {mac-address}] [interface {interface}] [vlan {vlan}]
Switch(config-if)#description {string}
A three-fold combination of 0 - 1 and X (don't care)
Layer 2 source and destination MAC addresses; Layer 3 Time-To-Live (TTL) value and header checksum
47. What are the administrative modes of Layer 2 switched interfaces?
Cisco Express Forwarding
Static access - trunk - tunnel or dynamic
Per port collision domains; Full duplex mode; Dedicated bandwidth; Error detection; Broadcast thresholds; Intelligent filtering and forwarding
Switch(config)#errdisable detect cause pagp-flap
48. Displays entries in the Forwarding Information Base (FIB) for a specific interface
Switch(config)#define interface-range {macro-name} {type} {module}/{number} [- {number}] [ - {type} {module}/{number} ...]
A three-fold combination of 0 - 1 and X (don't care)
Switch#show ip cef {interface} [detail]
Multilayer Switching
49. What is 100BASE-T4?
10 Gigabit Ethernet over 9 micron SMF (1310 nm serial laser)
The adjacency table
CEF glean
Fast Ethernet over 4 pairs EIA/TIA Category 3 - 4 - 5 UTP
50. What is ANSI?
Store-and-forward
Cisco Express Forwarding
A switch port that has been shut down automatically due to a serious error condition
American National Standards Institute