SUBJECTS
|
BROWSE
|
CAREER CENTER
|
POPULAR
|
JOIN
|
LOGIN
Business Skills
|
Soft Skills
|
Basic Literacy
|
Certifications
About
|
Help
|
Privacy
|
Terms
|
Email
Search
Test your basic knowledge |
Power Engineering 4
Start Test
Study First
Subject
:
engineering
Instructions:
Answer 45 questions in 15 minutes.
If you are not ready to take this test, you can
study here
.
Match each statement with the correct term.
Don't refresh. All questions and answers are randomly picked and ordered every time you load a test.
This is a study tool. The 3 wrong answers for each question are randomly chosen from answers to other questions. So, you might find at times the answers obvious, but you will see it re-enforces your understanding as you take the test each time.
1. Analog to digital converters (ADC)
Steam separators
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
Natural gas treatment plants remove
The devices which are used to change pneumatic signals to computer signals are known as...
2. Operates on either DC or AC and up to 60Hz
The universal series motor
The advantages of oil over coal as a boiler fuel are...
A passage way of at least ______ metres in width and clear of all obstructions shall be provided on both sides and the rear of the boiler
Transformers are cooled by...
3. 690kPa
Part of a total energy system
The photocell - when used in flame failure detection...
The blow- off tank for a boiler operating at 2200 kPa must have a design pressure of at least
The main opposition to current flow in a motor is...
4. The better voltage regulation
For DC generators - the nearer to zero the percentage voltage regulation is then
Multimeters are sometimes protected by...
The formation of carbon monoxide in the furnace is undesirable because it is...
A centrifugal switch used with an AC motor
5. Star- delta - line impedance and auto- transformer starting
Method used to start a 3 phase induction motor
The main opposition to current flow in a motor is...
Ohmmeters are for...
Multimeters are sometimes protected by...
6. Area
The rotameter is capable of measuring flow using a constant pressure differential and a variable
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
Type of electrical supply is used by electrostatic precipitators
Foundations for machinery are required to...
7. Counter emf
Properly planned maintenance
Limp diaphragms for sensing elements are sometimes made from...
The universal series motor
The main opposition to current flow in a motor is...
8. Analyze the flue gas
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
Method used to start a 3 phase induction motor
The universal series motor
Before making adjustments or altering the fuel- air ratio of a combustion control system - the power engineer should
9. Stability of operation
Correct for complete combustion
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
Ohmmeters are for...
A surge tower used in hydro electric generation stations is for...
10. 1. remove gasoline constituents 2. remove liquefiable hydrocarbons
The purpose of the recovery of the L.P.G. and gasoline process - used in a natural gas treatment plant is to...
A Third Class Engineer's Certificate of Competency qualifies the holder to work as a Chief Engineer for a power plant not exceeding
The devices which are used to change pneumatic signals to computer signals are known as...
The blow- off tank for a boiler operating at 2200 kPa must have a design pressure of at least
11. Stationary electrical charges
Correct for complete combustion
Plant safety committees should be made up of people from
Extinguisher that would ordinarily be used to combat a Class C fire
Magnetic fields do not interact with
12. An absorption chiller - generator - waste heat boiler and a heat pump
In an orifice meter - the vena contracta is the point where the...
Part of a total energy system
A Third Class Chief Engineer should be familiar with the following maintenance management areas
Complete combustion will take place only when
13. Management - supervisors and operators
The resistance of a conductor does not depend on its...
The purpose of the recovery of the L.P.G. and gasoline process - used in a natural gas treatment plant is to...
Plant safety committees should be made up of people from
Complete combustion will take place only when
14. 2H2 + O2 = 2H2O
Correct for complete combustion
Extinguisher that would ordinarily be used to combat a Class C fire
Multimeters are sometimes protected by...
The blow- off tank for a boiler operating at 2200 kPa must have a design pressure of at least
15. Place the core in oil filled tanks and cooling fans
Transformers are cooled by...
A Third Class Engineer's Certificate of Competency qualifies the holder to work as a Chief Engineer for a power plant not exceeding
Good housekeeping in a power plant is the responbility of the Chief Engineer as implied by the...
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
16. Safety Codes Act
The swing check valve...
The factors that determine the severity of electrical shock are...
The rotameter is capable of measuring flow using a constant pressure differential and a variable
Boiler and Pressure Vessel Safety is regulated by...
17. 1. hydrocarbon condensate 2. non - combustible gases 3. sulfurous compounds 4. water vapour
The total currents away from a point equal
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
Natural gas treatment plants remove
Plant safety committees should be made up of people from
18. The sum of currents into the point
A Third Class Chief Engineer should be familiar with the following maintenance management areas
The advantages of oil over coal as a boiler fuel are...
The power factor of an AC circuit is equal to...
The total currents away from a point equal
19. 10 000 kW
Properly planned maintenance
The devices which are used to change pneumatic signals to computer signals are known as...
A Third Class Certificate of Competency enables the holder to work as a shift Engineer of a power plant not exceeding...
The purpose of the recovery of the L.P.G. and gasoline process - used in a natural gas treatment plant is to...
20. Continuity measurements and direct resistance measurement
Ohmmeters are for...
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
Plant safety committees should be made up of people from
The rotameter is capable of measuring flow using a constant pressure differential and a variable
21. 5000 kW
Warning
: Invalid argument supplied for foreach() in
/var/www/html/basicversity.com/show_quiz.php
on line
183
22. Absorb vibration from both prime mover and driven machine
Steam separators
Foundations for machinery are required to...
The advantages of oil over coal as a boiler fuel are...
A surge tower used in hydro electric generation stations is for...
23. Safety Codes Act and Workers Compensation Act
Plant safety committees should be made up of people from
The power factor of an AC circuit is equal to...
Good housekeeping in a power plant is the responbility of the Chief Engineer as implied by the...
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
24. Will decrease cell resistance when a flame is detected
Properly planned maintenance
Method used to start a 3 phase induction motor
The photocell - when used in flame failure detection...
Part of a total energy system
25. Less storage problems - less handling equipment and less laabour requried
The factors that determine the severity of electrical shock are...
Before making adjustments or altering the fuel- air ratio of a combustion control system - the power engineer should
The advantages of oil over coal as a boiler fuel are...
Natural gas treatment plants remove
26. Outside of the boiler being cleaned
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
A surge tower used in hydro electric generation stations is for...
Transformers are cooled by...
The power factor of an AC circuit is equal to...
27. Mass
Plant safety committees should be made up of people from
A Third Class Chief Engineer should be familiar with the following maintenance management areas
Magnetic fields do not interact with
The resistance of a conductor does not depend on its...
28. 1. time of current flow through the body 2. the path taken 3. the quantity of the current
Properly planned maintenance
The resistance of a conductor does not depend on its...
A centrifugal switch used with an AC motor
The factors that determine the severity of electrical shock are...
29. Cathode ray oscilloscope and a picture tube
Boiler and Pressure Vessel Safety is regulated by...
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
A surge tower used in hydro electric generation stations is for...
Transformers are cooled by...
30. Explosive - poisonous and non - combustible
Limp diaphragms for sensing elements are sometimes made from...
A Third Class Chief Engineer should be familiar with the following maintenance management areas
The formation of carbon monoxide in the furnace is undesirable because it is...
A Third Class Certificate of Competency enables the holder to work as a shift Engineer of a power plant not exceeding...
31. Changes starting conditions to runnign conditions
A centrifugal switch used with an AC motor
The advantages of oil over coal as a boiler fuel are...
Correct for complete combustion
The formation of carbon monoxide in the furnace is undesirable because it is...
32. Fluid has the smallest cross sectional area
The factors that determine the severity of electrical shock are...
Natural gas treatment plants remove
In an orifice meter - the vena contracta is the point where the...
A centrifugal switch used with an AC motor
33. Carbon dioxide and dry chemical
Transformers are cooled by...
Before making adjustments or altering the fuel- air ratio of a combustion control system - the power engineer should
Extinguisher that would ordinarily be used to combat a Class C fire
The rotameter is capable of measuring flow using a constant pressure differential and a variable
34. Rubber
Transformers are cooled by...
Limp diaphragms for sensing elements are sometimes made from...
Magnetic fields do not interact with
The blow- off tank for a boiler operating at 2200 kPa must have a design pressure of at least
35. Offers little flow resistance
Type of electrical supply is used by electrostatic precipitators
Before making adjustments or altering the fuel- air ratio of a combustion control system - the power engineer should
The swing check valve...
The photocell - when used in flame failure detection...
36. Reduces uplanned outages of equipment
A centrifugal switch used with an AC motor
Properly planned maintenance
Good housekeeping in a power plant is the responbility of the Chief Engineer as implied by the...
Limp diaphragms for sensing elements are sometimes made from...
37. 1. preventative maintenance 2. management information system 3. work order system
A Third Class Certificate of Competency enables the holder to work as a shift Engineer of a power plant not exceeding...
The purpose of the recovery of the L.P.G. and gasoline process - used in a natural gas treatment plant is to...
A Third Class Chief Engineer should be familiar with the following maintenance management areas
In an orifice meter - the vena contracta is the point where the...
38. Circuit over load protection
The main opposition to current flow in a motor is...
A example of an image tube whose function is the generation and display of a light image from an electrical input signal is...
The total currents away from a point equal
Multimeters are sometimes protected by...
39. The cosine of the phase angle
A Third Class Engineer's Certificate of Competency qualifies the holder to work as a Chief Engineer for a power plant not exceeding
A Third Class Chief Engineer should be familiar with the following maintenance management areas
Safety valves shall be designed to attain full lift at a pressure above set pressure but not exceeding
The power factor of an AC circuit is equal to...
40. 3%
A hydrostatic test consists of completely filling the boiler with water and the applying a water pressure
Limp diaphragms for sensing elements are sometimes made from...
Safety valves shall be designed to attain full lift at a pressure above set pressure but not exceeding
The blow- off tank for a boiler operating at 2200 kPa must have a design pressure of at least
41. 0.6
Good housekeeping in a power plant is the responbility of the Chief Engineer as implied by the...
Ohmmeters are for...
A passage way of at least ______ metres in width and clear of all obstructions shall be provided on both sides and the rear of the boiler
Power for operating mechanical cleaning tools used in removing scale or slag from firetube boilers shall be generated...
42. DC
The purpose of the recovery of the L.P.G. and gasoline process - used in a natural gas treatment plant is to...
The swing check valve...
A passage way of at least ______ metres in width and clear of all obstructions shall be provided on both sides and the rear of the boiler
Type of electrical supply is used by electrostatic precipitators
43. 1. the temperature of the fuel- air mixture will be at least equal to the ignition temperature. 2. there is sufficient oxygen present for combustion. 3. the oxygen is in intimate contact with the fuel.
Complete combustion will take place only when
In an orifice meter - the vena contracta is the point where the...
Ohmmeters are for...
A Third Class Certificate of Competency enables the holder to work as a shift Engineer of a power plant not exceeding...
44. 1.5 times the maximum allowable working pressure
A hydrostatic test consists of completely filling the boiler with water and the applying a water pressure
The swing check valve...
Plant safety committees should be made up of people from
Steam separators
45. 1. cause the steam to suddenly change its direction 2. impart a whirling motion to the steam 3. baffles cause the steam flow to change direction 4. are sometimes called steam purifiers
Plant safety committees should be made up of people from
The rotameter is capable of measuring flow using a constant pressure differential and a variable
Properly planned maintenance
Steam separators