Test your basic knowledge |

Plumbing Code Basics

Subjects : industries, plumbing
Instructions:
  • Answer 50 questions in 15 minutes.
  • If you are not ready to take this test, you can study here.
  • Match each statement with the correct term.
  • Don't refresh. All questions and answers are randomly picked and ordered every time you load a test.

This is a study tool. The 3 wrong answers for each question are randomly chosen from answers to other questions. So, you might find at times the answers obvious, but you will see it re-enforces your understanding as you take the test each time.
1. Water piping for the distribution of hot or cold water within buildings shall be of materials rated for not less than_____ psig.






2. What is the minimum discharge pipe size for a grinder pump which discharges 45gpm?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


3. What is the maximum length you can run a 1 1/2 inch vent off a 75 gallon per minute sump pump?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


4. What is the maximum spacing between fixtures on a continuous waste?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


5. What is the minimum condensate pipe size for a 300 ton cooling unit?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


6. Mechanically formed tee fittings shall have depth stops provided ____ above the dimple that acts as a depth stop.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


7. On a threaded piece of 1 1/4 inch black steel gas pipe - How many threads should be cut on the pipe?






8. What size vent stack is needed for a 160' tall building with 6 branch intervals each having 23 drainage fixture units per branch?






9. Metallic drip pans shall be a minimum ____ gage.






10. What size pipe is needed for a combination waste and vent stack with a total of 400 drainage fixture units at 1/4 inch per foot slope?






11. A 2 inch type L copper water branch shall be supported at _____ intervals.






12. The vertical distance from the fixture outlet to the trap weir shall not exceed ____.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


13. Conductor is a storm pipe ____.






14. Each trailer site shall be provided with a ____ ips male or female threaded connection - extended above grade - from a ____ minimum size vented p-trap.






15. Water may not be discharged onto the drainage system if temperature exceeds _____ degrees F.






16. How many gallons of water would be in a tank which was 5' in diameter - 16' tall - and 3/4 full?






17. What is the maximum length for a 3' trap arm?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


18. ABS plastic pipes - schedule 40 or 80 May be used in which potable water installation?






19. What size storm sewer is needed for a building with a roof 45 feet wide and 85 feet long at 1/8 inch slope - located in boise - Idaho?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


20. What is the max dfu's permitted to be discharged into a 4' soil stack on a 3 story building?






21. Flexible plastic tubing shall be supported horizontally every ____'.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


22. What is the approximate length of threaded portion and approximate number of threads to be cut for a 3' pipe?






23. Rated flow velocities for grinder pump ejectors shall be not less than ____.






24. What is the maximum length for a 3' trap arm?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


25. What is the maximum length of a 2 inch trap arm?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


26. An air conditioning condensate pump which discharges 8 gpm would require a ____ inch horizontal drain.






27. An approved pressure reducing valve shall be provided where it is required to limit the water supply pressure but shall be no more than ____ psi.






28. Must be installed so that a swing check valve controls the flow of rate






29. What is the maximum distance a 2 inch vent can be run off a 76 gallon per minute sump pump?






30. What is the minimum pressure used to test gas piping with a working pressure less than 125 psi?






31. Clean-outs in horizontal drainage lines 4' or less shall be spaced at intervals not exceeding ____ feet.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


32. When testing a gas system - which can not be used? A). Air. B). Nitrogen. C). Oxygen. or D). B or C?






33. What is the maximum length for a 3' trap arm?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


34. Well pumps located in a basement shall have the pump and suction pipes at least ____' above the floor.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


35. When connecting additional gas pipe - check for...






36. Waste drainage from condensers or steam traps shall be cooled below ____ before being discharged indirectly into the sanitary drainage system.






37. Lead caulked joints for cast-iron hub & spigot soil pipe shall be firmly packed with oakum or hemp & filled with molten lead not less than____'.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


38. What's the maximum dfu's permitted on a 6' sewer at 1/4' per foot?






39. Vitrified clay pipe installed underground within buildings shall have____ ' minimum earth cover.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


40. Sump pits shall be a minimum of ____ inches in diameter and ____ inches in depth.






41. Water may not be discharged onto the drainage system if temperature exceeds _____ degrees F.






42. In food handling establishments - all openings through floors shall be sleeved and projecting not less than ___ above the top of finished floor.






43. Vent pipes in trailer parks shall be located at least ____ above grade.






44. Grease interceptors shall have a grease retention capacity of not less than ____ pounds for each gpm of flow.






45. A 3' horizontal drain at a 1/4' per foot grade would have a discharge velocity of ____.






46. What size water softener connection is required for two bathroom groups?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


47. Underground gas piping not in conduit shall have a minimum cover of ____ inches.

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


48. A sewer runs 375' long at 3% grade - how many inches is the drop?

Warning: Invalid argument supplied for foreach() in /var/www/html/basicversity.com/show_quiz.php on line 183


49. Used - untreated water that is flushed down toilets and urinals is called ____.






50. Materials fr pvc sewer pipe & fittings installed for foundation and sub-soil drainage shall conform to ASTM ____.